BXJTM - ROYCO 49B
- MSDS: BXJTM
- Manufacturer: ROYAL LUBRICANTS CO INC
- Product Name: ROYCO 49B
- National Stock Number: 9150-00-235-5555
Product Identification
Product ID:ROYCO 49B
MSDS Date:04/21/1992
FSC:9150
NIIN:00-235-5555
MSDS Number: BXJTM
Responsible Party
EAST HANOVER, NJ 07936
US
Emergency Phone: 201-887-7411/800-424-9300
Info Phone: 201-887-7410
Cage: 6V632
Contractor
Telephone: 201-887-7410
Cage: 6V632
Ingredients
SOLVENT REFINED HYDROTREATED RESIDUAL OIL
CAS: 64742-57-0
Fraction By Weight: 70-80%
BENTONITE CLAY 27
CAS: 68953-58-2
RTECS: UZ2996400
Fraction By Weight: 10-15%
MOLYBDENUM DISULFIDE
CAS: 1317-33-5
RTECS: QA4697000
Fraction By Weight: 3-8%
OSHA PEL 10 MG MO/M3
ACGIH TLV: 10 MG MO/M3
SODIUM NITRITE (CERCLA)
CAS: 7632-00-0
RTECS: RA1225000
Fraction By Weight: <3.0%
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
BARIUM DINONYLNAPHTHALENE SULFONATE
CAS: 25619-56-1
Fraction By Weight: <1.0%
ADDITIVES
Fraction By Weight: <10%
Hazards
LD50 LC50 Mixture:PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE-EYE:MILD IRRITATION.
SKIN:DERMATITIS,FOLLICULITIS,OI ACNE POSSIBLE FROM PROLONGED &/OR
REPEATED SKIN CONTACT. HIGH PRESSURE INJECTION UNDER SKIN MAY CAUSE
NECROSIS. INHALATION:NOT EXPECTED TO BE A SIGNIFICANT ROUTE OF
EXPOSURE. VAPORFROM HEATING MAY CAUSE IRRITATION. INGESTION:NO
SPECIFIC INFORMATION IDENTIFIED.
Explanation of Carcinogenicity:DOES NOT CONTAIN ANY CARCINOGEN
IDENTIFIED BY IARC, NTP OR OSHA.
Effects of Overexposure:IRRITATION AS NOTED IN HEALTH HAZARDS. NECROSIS
FROM HIGH PRESSURE INJECTION IS EVIDENCED BY DELAYED ONSET OF PAIN
& TISSUE DAMAGE A FEW HOURS FOLLOWING INJECTION.
Medical Cond Aggravated by Exposure:PRE-EXISTING EYES AND SKIN DISORDER
MAY BE AGGRAVATED TO EXPOSURE TO THIS PRODUCT.
First Aid
First Aid:IF IRRITATION PERSISTS OR IS SEVERE, GET MEDICAL ATTENTION.
EYE:FLUSH W/WATER FOR 15 MIN. SKIN:SCRAPE OFF & WASH AREA W/SOAP &
WATER. REMOVE CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE.
INHALED:REMOV E FROM EXPOSURE. AID OR RESTORE BREATHING AS NEEDED.
INGESTED:DO NOT INDUCE VOMITING. EVEN THOUGH NO TREATMENT IS
NECESSARY FOR MINIMAL INGESTION, GET MEDICAL ADVICE.
Fire Fighting
Flash Point Method:COC
Flash Point:>410F,>210C
Extinguishing Media:USE WATER FOG, CO2, DRY CHEMICAL, FOAM, DO NOT USE
DIRECT WATER STREAM. PRODUCT WILL FLOAT AND MAY REIGNITE.
Fire Fighting Procedures:DO NOT ENTER CONFINED FIRE SPACE W/O PROPER
PROTECTIVE EQUIPMENT & NIOSH APPROVED SCBA. COOL FIRE EXPOSED
CONTAINERS SURROUNDING EQUIPMENT & STRUCTURES W/WATER.
Unusual Fire/Explosion Hazard:MFR GAVE NO INFORMATION ON MSDS.
Accidental Release
Spill Release Procedures:SCOOP UP EXCESS GREASE.CLEAN AREA W/
APPROPRIATE CLEANER. PRODUCT IS CLASSIFIED AS AN OIL. REPORT ANY
SPILL THAT CAUSES A SHEEN PER CLEAN WATER ACT REQUIREMENTS. RQ =
3,200 POUNDS.
Neutralizing Agent:MFR GAVE NO INFORMATION ON MSDS.
Handling
Handling and Storage Precautions:STORE IN COOL, DRY W/ADEQUATE
VENTILATION. KEEP AWAY FROM OPEN FLAMES & HIGH TEMPERATURE.
MINIMIZE SKIN CONTACT.
Other Precautions:WASH W/SOAP & WATER BEFORE EATING, DRINKING, SMOKING
OR USING TOILET. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
PROPERLY DISPOSE OF CONTAMINATED LEATHER ARTICLES INCLUDING SHOES
THAT CANNOT BE DECON TAMINATED.
Exposure Controls
Respiratory Protection:NOT ORDINARILY REQUIRED.
Ventilation:MFR GAVE NO INFORMATION ON MSDS.
Protective Gloves:OIL RESISTANT
Eye Protection:EYE PROTECTION FOR HIGH PRESSURE USE
Other Protective Equipment:USE OIL RESISTANT GLOVES & OTHER CLOTHING AS
NEEDED TO MINIMIZE SKIN CONTACT.
Work Hygienic Practices:MFR:? HMIS:USE GOOD INDUSTRIAL HYGIENE
PRACTICES. MINIMIZE CONTACT & WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE
Chemical Properties
HCC:V6
NRC/State Lic Num:NONE
Solubility in Water:INSOLUBLE
Appearance and Odor:BLACK BUTTERY GREASE, SLIGHT ODOR
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENT
Stability Condition to Avoid:HEAT,OPEN FLAME
Hazardous Decomposition Products:HIGHLY DEPENDENT ON COMBUSTION
CONDITONS. COMPLEX MIXTURE OF AIRBORNE SOLID/LIQ PARTI/GASES; CO &
UNK ORGANIC COMPOUNDS.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:PRODUCT CONTAINS BARIUM (WASTE NO. D005) & MAY
TEST POSITIVE TCLP. MATERIAL MAY BE RECYCLED OR BURNED FOR ENERGY
RECOVERY. REFER TO EPA & STATE REGULATIONS REGARDING RECYCLE OR
DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.